The role of electric gourd work level detailed classification

2024-05-23

Z

The previous article summarized the working level of the electric gourd and the subdivision categories below. The following description of the role of each detailed classification is explained, and it has a more comprehensive understanding.

S1 continuous work system: The running time under the constant load is sufficient to achieve heat stability.

S2 short -term working system: Run at the given time under the constant load. This time is not enough to achieve thermal stability. Then it can stop enough time to stop the motor again to cooler the temperature and the temperature of the cooling medium within 2K.

S3 intermittent cycle work system: run according to the same series of working cycles, each cycle includes a constant load running time and a period of disconnecting energy. The starting current of each cycle in this working system does not have a significant impact on the temperature rise.

The S4 includes the starting cycle work system: run according to the same series of working cycles. Each cycle includes a starting time that has a significant impact on Wen Sheng, a constant load running time, and a period of disconnection.

The S5 includes the intermittent cycle working system of the electrical brake: runs according to the same series of working cycles, each cycle includes a starting time, a constant load running time, a fast electronic dynamic time, and a period of disconnecting energy.

S6 continuous cycle work system: run according to the same series of working cycles. Each cycle includes a constant load running time and an empty load running time, but there is no disconnection time.

The S7 includes the continuous cycle working system of the electronic brake: run according to the same series of working cycles, each cycle includes a starting time, a constant load running time, and a fast electronic dynamic time, but there is no disconnection time.

The S8 includes the continuous cycle working system of the transmission load: run according to a series of the same working cycle. Each cycle includes the running time of the constant load running time at the predetermined speed, and the running time of other constant loads of other constant loads at different speeds. , But there is no disconnection time.

S9 load and non -cyclical change working system: non -periodic work system that changes in the load and speed within the allowable range. This working system includes frequent overloads, and its value can far exceed full load.

There will be a certain gap between the working system and working level of each electric gourd. If there are requirements for the work level, you must inform customer service when purchasing electric gourds, which is convenient to recommend more suitable electric gourd products.